Fluke T+Pro Electrical Tester

Safer than solenoid testers and fully compliant with NFPA 70E, (when used properly per Article 110.4 Use of Equipment (A) Test Instruments and Equipment), the T+Pro helps electricians and technicians work safer by indicating the presence of voltage, even when the batteries are dead. Additional functionality, such as a GFCI trip, easy to read LCD screen, resistance measurement up to 9.99 k?, and a built-in flashlight make the T+Pro the first voltage tester that electricians reach for.

How to use the Fluke T+ Pro Electrical Tester

The Fluke T+Pro Electrical Tester indicated AC/DC voltage in three different ways:

  • Light
  • Sound
  • Vibration
 
Security policy

(edit with the Customer Reassurance module)

 
Delivery policy

(edit with the Customer Reassurance module)

 
Return policy

(edit with the Customer Reassurance module)

PRODUCT FEATURES

  • Detect live voltage, see voltage level, even with dead batteries
  • 3 forms of AC/DC voltage indication: light, sound, and vibration
  • Backlit LCD display and hold function for easier viewing

SPECIFICATIONS

Temperature

Operating: -10?C to 55?C (14?F to 131?F)

Storage:? -30?C to 60?C (-22?F to 140?F)

Relative Humidity

90%: 0?C to 30?C (32?F to 86?F)

75%: 30?C to 40?C (86?F to 104?F)

45%: 40?C to 50?C (104?F to 122?F)

Altitude

Operating: 2,000 m (approx. 6,561.6 ft)

Storage: 10,000 m (approx. 32,808.4 ft)

Battery Type/Life: AAA (2); 40 hours

Shock, Vibration: Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument

Safety: ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV, Compliance to NFPA 70E1

AC Bandwidth: 45 Hz to 66 Hz

Maximum Working Voltage: 1000 V AC/DC

Maximum Measurable Voltage: 600 V AC/DC

Duty Cycle: Indefinitely for voltages up to 240 V

For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off

For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s

Voltage Hazard LED: LEDs turn on at voltages > 30 V AC/DC ?35%

LED Voltage Indication Levels: 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V

LEDs: LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100%

LCD Accuracy

AC voltage: ?(3% rdg + 2 digits)

DC voltage: ?(2% rdg + 2 digits)

Resistance: ?(5% rdg + 3 digits)

LCD Resolution: 0.1 V for voltages < 50 V, 1 V for voltages >= 50 V

0.01 k? for resistance measurement

GFCI Test Current: 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA

Standard Input Test Current: < 5 mA

Size (H x W x L) : 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm )

Weight: 9.9 oz (0.28 kg)

Comments (0)